Hot!

Curriculum Vitae


clip_image003[10]

Ari Sulistiono

  • Male, 28 years old
  • Jl. Sidoluhur II No. 47
  • Ds. Jati, Kec. Tarokan
  • Kediri – Jawa Timur 16951
  • Phone: hidden for cyber-security reason
  • Mobile No.: hidden for cyber-security reason
  • Email: Click this to email me!
  • website: arisulistiono.blogspot.com 

Objective

Electrical Engineer, Instrument Engineer, Automation Engineer, Commissioning Engineer” » 5 yearsexperience on electrical engineering field

Graduate

  • State Polytechnic of Jakarta (Polytechnic of University of Indonesia) 2002 – 2005.
  • Date of graduate : September 29th, 2005.
  • Final Thesis Title: “Design Software MMI (Man Machine Interface) and Design Fuzzy Distributed Intelligent Control System using Microcontroller AT89S52”, Score: A (91 of 100)
  • Last GPA: 2.83 of four scales.

Bio

  • Birthday: Kediri, March 27th, 1984
  • Sex: Male
  • Status: Single
  • Religion: Moslem
  • Nationality: Indonesian

Education Attainments

FORMAL EDUCATION
  • 2002-2005: D3 State Polytechnic of Jakarta (Polytechnic of Indonesia University) majoring Electrical Engineering
  • 1999-2002: Senior High School SMUN 1 Grogol in Kediri, East Java
  • 1996-1999: Junior High School SMPN 1 Tarokan in Kediri, East Java
  • 1990-1996: Elementary School SDN 02 Jati in Kediri, East Java
NON FORMAL EDUCATION
  • 2004: Basic applications of Programmable Logic Controller (PLC) and SCADA system in industrial automation system, PNJ kampus baru UI-Depok.
  • 2004: Public Lectures: pneumatic control system, presented by Festo, kampus baru UI Depok.
  • 2003: Management training and organizational, BEM & Trusco, kampus baru UI Depok.
  • 2002: Public lectures: GPRS Technology, kampus baru UI Depok, presented by: Nokia and IM3
  • 2002: Public Lectures: LabView Application for Automation and Robotic system 
  • 2002: Microprocessor and Microcontroller Application for Industrial Control System Seminar, at Polytechnics State of Jakarta
  • 2002: Basic Training of Leadership Collaboration PNJ with Indonesian Marines, Location: Brigif 2 MarinirCilandak and Bumi Perkemahan Cibubur
  • 2006: Training AutoCAD 2D & 3D, Binus Training Center, Kedoya – Jakarta Barat.
  • 2006: Protection Relaying System and GE – UR Multilin Programming and Protocol, General Electric.
  • 2006: Cable Fault Location and Analysis via Partial Discharge Mapping & Impulse Test, Hagenuk & SEBA-KMT, Germany.

Additional Skills

Computer Skills:
  • Microsoft Office: Microsoft Word, MS Excel, MS Power Pont, Microsoft Visio, Microsoft FrontPage, Microsoft Project
  • Primavera Project: Primavera P3, SureTrak, Primavera Project Planner Essential
  • Drawing: AutoCAD 2D - 3D, El-CAD, Protel PCB & Schematic, AutoCAD Electrical 2011, Microsoft Visio, Photoshop, Flash (3D), Freehand.
  • Database: Microsoft Access, Microsoft Jet ADODB, Microsoft SQL Server, MySQL, XML
  • Programming Language: Visual Basic 6.0, Visual Studio.Net, C++, Assembler, PHP, HTML, ASP, PERL.
  • E-Tap Powerstation 7.0 (Design, Calculate & Power System Analysis)
  • SCADA Power System (Citect) algorithm design, programming and installation.
  • Software I have created and developed for electrical engineering training: Mini-simulation SCADA/HMI for Chemical Batch Plant, Microcontroller Programmer, Fuzzy Logic Evaluator, Multimedia Laboratory for Electrical Machine Drive Control Simulation, 3ph Motor Components Calculator, Control & Simulation of Servo Control, Input/Output Simulation and Testing of Ladder Diagram (PLC), Mini Water Treatment Monitoring System, PLN CBM Monitoring & Data Logging System for 150kV Bay Switchyard, etc.
Digital Control:
  • Installation, programming and troubleshooting PLC (hardware & software). PLC brand that has been used: Omron, LG, Mitsubishi, Schneider, Siemens, Idec, Yokogawa, Allen Bradley.
  • Microcontroller & Microprocessor programming (ASM, C, Ladder) and build software for integration between plant to microcontrollers.
  • Data Link and Monitoring System: PC/Server to Devices via Modbus, DNP, IEC or other open protocols using software (citect, excel/vb script, Visual Studio.Net, LabView).
Electrical & Instrumentation Skills:
  • Able to create and read engineering/technical drawings (electrical).
  • Excellent electrical and design capability, with ability to disassemble, repair, replace, install, and reassemble parts, and make adjustments to equipment based on international standard (IEC) and manufacturer specifications.
  • Protective Relays: UR Relay – GE Multilin, Siprotec series – Siemens, ABB – REL series, Toshiba – GRZ & GRL, Areva – Micom Series, Schneider – SEPAM Series.
  • Design and develop a software/HMI/SCADA for Power & Energy Monitoring over devices protocol using any digital devices which support open protocols and data communication capability.
  • Primary & Secondary Injection test for HV Equipments nor Protective Relaying. Capable for operate any injection kits (Omicron CPC series and CMC series, ISA DRTS series, KoCoS, GE Programma, etc.)
  • HV Current Transformer FAT & SAT: Ratio, Knee-point, Burden, and CT Characteristic Test.
  • Battery & Battery Charger Installation, Load/Capacity Test & Commissioning.
  • Partial Discharge Test & Detection for Underground Cable and switchgear.
  • Design, calculation and analysis of new power plant, substation/switchyard, transmission network and distribution of power with e-tap PowerStation software or manual calculation.

On The Job Training

  • Practical Work: - P.T. Cipta Rantau Mandiri Comp. As Computer Trainer - freelance (2004, 1 Months)
  • P.T. Hibec Indonesia (2003, 2 months) as connector maker (freelance): Assembly Connector Cable for Musical Instrument Test Set.
  • P.T. Citra Langgeng (2003, 2 months) as display maker (freelance): digital display, error-assembling detectors (for Yamaha Music Manufacturing Asia).
  • C.V. Pratama teknik terapan as PLC programming trainer: PLC training, PT. Neomax, Krakatau Steel Industrial Estate (2005), and PLC programming training to the public and students, Kampus Baru UI Depok (2005).
  • P.T. Anavasi as sensor designer: high frequency detector for analyzes the pianos tweeter, March – November 2005.

Organization Experience

  • Himpunan Mahasiswa Elektro, Secretarial Division, Politeknik Kampus Baru UI Depok, 2002-2003.
  • Badan Eksekutif Mahasiswa, Public Relations Division, Politeknik Kampus Baru UI Depok, 2004-2005.

Experimental Projects

  • Development of laboratory of control system base on the multimedia and simulation using macromedia flash 4.0, August 2005, DIKMENTI, Ciwaruga - Bandung.
  • Implementation of theory fuzzy set by computer as controller of speed of rotation of motor dc servo, August 2005, DIP-PNJ, Kampus Baru UI Depok – Jawa Barat.
  • Design software and controller (automatic & remote operation) for controlling a 3-phases induction motor, September 2005, DIKS-PNJ, Kampus Baru UI Depok – Jawa Barat.
  • Design soft-panel for control system test & simulation (for PLC exercise) without actual objects, September 2005, DIP-PNJ, Kampus Baru UI Depok – Jawa Barat.
  • Sensitive color censor for detects wrong manual book inserted and reduce “packing human error”. Manual book for each country has different color indication and if operator mistake while packing, it will be alarm. July 2005, PT YMMA (Yamaha Music Manufacturing Asia).
  • Direct Control System uses the parallel port of computer, August 2005, DIKS-PNJ, Kampus Baru UI Depok – Jawa Barat.
  • e-Tap Powerstation 6.0 + Substation Automation Simulation Program for PLN 150kV Grid, PLTU Muara Karang, Jakarta Utara.

Achievements

  • National competitions of scientific works and research for university students, Dirjen Pendidikan Tinggi, UMM - Malang, East Java, June 2006.

Working Experiences

1. PT. Dinamika Elektra Mandiri, as “Senior Electrical Engineer” start in January 2006 – February 2008. Project Experiences at PT Dinamika Elektra Mandiri:
  • Change over ES PLTG to PLTD and Installation of Double Feeder from ES1 to SWS1 Pertamina UP II Dumai – Indonesia: Programming and Setting of relays protection, UR GE Multilin - Canada, such as protection element, logic control, TCP/IP address, transfer & remote operation, Auto Synchronous Transformator, Auto transfer Switch (ATS), Relay Blocking, Metering and Display Configurations, etc. January – March 2006.
  • Installation of Partial Discharge Monitoring for switchgears insulation. Location: main substation PLN kebun sirih, Indipard 16 – May Electronic Germany: Designing of the control, installing device, & programming the device. March 2005.
  • Partial Discharge Mapping on 20kV underground cable: Collecting data of underground cable using OWTS equipment and determine weak point of the cable. Location: All Jakarta Area (Distribution 20kV) – PLN Distribusi Jakarta - Tangerang March – April 2006.
  • Design software “Multifunction Power Quality Meter”: this software pooling the data each hour from any revenue meters via ModBus protocol. Tested and implemented at PLN using energy meter Shark 100 & 100 T (Electro Industries). Location: PLN UPT Karet & UPT Cawang, April 2006.
  • Installation of battery (NiCad) and battery charger 230V 600Ah. Location: Indonesia Power Tanjung Priuk. March 2006.
  • Build system integrator between line transmission – power meter – operator – management – maintenance staff for supporting CBM (Condition Based Maintenance) program on PLN. Component used are power digital meter shark100, modbus protocol, and visual basic 6.0.
  • As Trainer in Automatic Relay Test System Training, Oil & Gas Comp., Cnooc SES – Offshore, August ’06.
  • Installation & Commissioning Digital Power Meter: PLTU Indonesia Power Tambak Lorok– Semarang, September 2006.
  • Site Acceptance Test for Generator Protection Relay “Elin” + CT Saturation contracted by GE Turbine – France: Cikarang Listrindo, Cikarang, April ’06.
  • Test & Calibration Star-Relay contracted by GE Turbine – France: Pupuk Kujang, Kerawang, April ’06.
  • Design Power & Energy Monitoring + Installation of Digital Power & Energy Meter Shark100 – PLN P3B Region Center of Java & DI Yogyakarta, November 2006.
  • Test & Callibration Elin - Differential Relay for Generator contracted by GE Energy: Cikarang Listrindo, June ’06.
  • Test & Callibration Distance Relay REL511 C1*2.5 + Overcurrent Relay contracted by ABB Transmission & Distribution – Tangerang, November 2006.
  • Installation & Commissioning of Digital Power and Energy Meter ‘Shark100 – Electro Industries (USA)’ + Build Real Time Monitoring Software for Supporting CBM (Condition Base Maintenance) ‘CrazPro.exe’ – VB.Net. Location: PLN P3B – RJTD : UPT Solo, UPT Kudus, UPT Purwokerto, UPT Jogja, UPT Semarang on December, 2006.
  • Installation & Commissioning of Online Partial Discharge Monitoring ‘Indipard – May Elektronik, Gambh’ for Switchgear 12kV, Location: CNOOC – South East Sumatra (Offshore) on November, 2006.
  • Installation of Retraceable Grounding Assembly (RGA) 44 Units at Tank Farm Area. Location: Total E&P Balikpapan, January - February 2007.
  • Perform Relay Test & Callibration for Generator Protection Relay – Generator #2015 UA. Location: Pertamina UPIII Plaju, Palembang, March 2007.
  • Conduct Training: Installation and Operation of Revenue Meter, 0.06 Class Accuracy ‘Nexus 1262’ – EIG (USA) for PLN P3B Jawa Bali. Location: Hotel Nikki, Denpasar, Bali on 27th – 29th March 2007.
  • Installation & Commissioning of Online Partial Discharge Monitoring ‘Indipard – May Elektronik, Gambh’ for Generator and CB Cubicle, Location: PT Freeport Indonesia: Puncak Jaya Power (FMI) – Papua on May 2007.
  • Contract Service To Perform Calibration And Verification For Unit 7 Protection Relay 13.8KV Medium Voltage Switchgear. Location: IPMOMI Paiton, Situbondo, East Java. June 2007.
  • Repair & Calibration Digital Revenue Meter 0.06% Class, 12 Units ‘Nexus 1262’ PLN P3B JB, June 2007.
  • As Sub Contractor Toshiba Corporation, Japan: Data collection for Renewal of Transmission Line Protection Relay Project at Siguragura P/S, Tangga P/S, and Kuala Tanjung S/S: GRZ100 Protection Relay 275kV. Indonesia Asahan Alumunium (Inalum), July 2007.
  • Power Quality Analysis & Data Collecting, Indah Kiat Pulp and Paper - Sumatra, PT. Contracted by GE Energy, Singapore. September 2007.
  • Design Bay Monitoring System for Trafo, Line, Coupler, & Feeder: CrazPro Power & Energy Monitoring 7 (develop using Visual Studio 2005, supporting Digital Power Meter 0.2S Shark 100) for PLN P3B JB RJTD UPT Solo & UPT Kudus. October 2007.
  • Installation & Commissioning of Online Partial Discharge Monitoring ‘Indipard – May Elektronik, Gambh’ for New Feeder Cubicle (Scneider), Location: Pertamina UP V Balikpapan, August 2007.
  • Sub Contract with Toshiba Corporation Japan (as Commissioning Engineer & Relay Test Operator): Execution of Renewal of 275 kV Transmission Line Protection Relay at Siguragura P/S (Nov. 2007), Tangga P/S (Dec. 2007), and Kuala Tanjung S/S (Jan. 2007): GRZ100. Client: Indonesia Asahan Alumunium, PT. Responsibility: Relay Testing, Erection & Cable Termination, Insulation Test, Sequence Check, Ass. Built Drawing, etc.
2. Sumitomo Corporation Switchyard & Substation (SCSS), as “Test & Commissioning Engineer” for 150kV Swutchyard and Substation - Muara Karang Gas Power Plant Project (MKGPP), Contract Period: 7thMarch 2008 up to 6th March 2010:
  • Assistance to Construction Service for procurement material and construction for PLTU Muara Karang (PLN) - Gas Power Plant Project (JBIC Loan).
  • Electrical studies: starting from basic design up to detail design of 150kV RCPP, Substation Automation & replacement method for Substation & Switchyard of PLTU Muara Karang, PLTGU Muara Karang, Duri Kosambi S/S, Petukangan S/S, Budi Kemuliaan S/S, Angke S/S.
  • 150kV PLTU Muara Karang Switchyard & Substation:
    • Design Protection Panel, ACDB, and Marshaling Kiosk.
    • Design cable connection list and schematic drawing.
    • Design Installation & Test Procedure for HV Equipments.
    • Conduct Individual Test for 150kV GIS (Gas Insulation System) & AIS (Air Insulation System) Switchyard (CT, CVT, CCVT, CB, DS, SA, LT, etc.) and analyzing data (based on IEC standard) per Diameter/Bay. Test included: Contact Resistance Test for Installation, SF6 moisture test, CT ratio test (Current Injection Method for AIS & Voltage Injection Method for GIS), CT secondary burden test, CT characteristic test (kneepoint), CT polarity test up to prot. panel, CVT ratio test, CVT secondary burden test, CVT polarity test, CB timing test, Contact Resistance Test for CB (Main Contact), Insulation Resistance for all Equipments, Disconnector Insulation Test, Disconnector Contact Resistance Test and High Voltage Test.
    • Conduct battery capacity test, rectifier and UPS test, and test and commissioning for ACDB and DCDB panel.
    • Change over from existing system to new system.
    • Conduct individual test for Control & Protection Panel “Siemens” using Relay test System “Omicron CMC356”: Line Differential Protection, Line Distance Protection Relay, OCR, Auto re-close, Bus Protection Relay, GFR, Soft Logic Interlocking, Bay Control Unit, GFR, Outstation metering, etc.
    • Collect and analyzing parameter of protection elements of the existing system and recalculate for change over to the new system arrangement (up-rating S/Y equipments & OHL from 1200A to 4000A).
    • Test & commissioning for Substation Control System and new telecommunication system (gateway, fiber optic and server) up to RCC (Region Control Center) and JCC (Jawa-Bali Control Center) SCADA System.
  • Duri Kosambi 150kV Substation:
    • Replacement of Bus Coupler, Bus Section, Busbar Conductor and Feeder Kebon Jeruk.
    • Conduct Individual Test (AIS) for HV Equipments (CT, CVT, CB, DS, etc.) and analyzing data (based on IEC standard) per Diameter/Bay. Test included: Contact Resistance Test for Installation, SF6 moisture test, CT ratio test (Current Injection Method for AIS & Voltage Injection Method for GIS), CT secondary burden test, CT characteristic test (kneepoint), CT polarity test up to prot. panel, CVT ratio test, CVT secondary burden test, CVT polarity test, CB timing test, Contact Resistance Test for CB (Main Contact), Insulation Resistance for all Equipments, Disconnector Insulation Test, Disconnector Contact Resistance Test and High Voltage Test.
    • Site survey and design cable connection list (cable schedule) for new control cable that connects new HV equipment installation to existing system installation.
    • Test & commissioning of new telecommunication system.
    • Design, test & commissioning for new AC/DC distribution panel.
    • Petukangan 150kV Substation:
    • Site survey and collect data for Busbar Replacement.
    • Design cable connection list for new bus protection panel up to existing system.
    • Test & Commissioning of Bus Protection Panel.
    • Test & commissioning for Substation Control System and new telecommunication system (gateway, fiber optic and server) up to RCC and JCC SCADA System.
    • Design, test & commissioning for new AC/DC distribution panel.
    • Conduct Individual Test (AIS) for HV Equipments (CT, CVT, CB, DS, etc.) and analyzing data (based on IEC standard) per Diameter. Test included: contact resistance test, insulation resistance test, SF6 moisture test, CT ratio-burden-kneepoint and polarity test, CVT ratio-burden and polarity test, CB and DS test.
  • 150kV PLTGU Muara Karang Baru Switchyard & Substation:
    • Design Protection Panel, ACDB, and Marshaling Kiosk.
    • Design cable connection list and schematic drawing.
    • Design Installation & Test Procedure for HV Equipments.
    • Conduct Individual Test (GIS and AIS) for HV Equipments (CT, CVT, CB, DS, etc.) and analyzing data (based on IEC standard) per Diameter. Test included: contact resistance test, insulation resistance test, SF6 moisture test, CT ratio-burden-kneepoint and polarity test, CVT ratio-burden and polarity test, CB and DS test.
    • Conduct test & commissioning for battery capacity/characteristic, battery charger (rectifier), UPS, AC Distribution Board and DC Distribution Board.
    • Change over from existing system to new system.
    • Conduct protection relay individual test (also End to End test): Line Differential Protection, Line Distance Protection Relay, OCR, Single Phase Autoreclose, Busbar Protection Relay, etc.
    • Collect and analyzing parameter of protection elements of the existing system and recalculate for change over to the new system arrangement.
    • Test & commissioning for Substation Control System (Substation Automation) and new telecommunication system (gateway, fiber optic and server) up to RCC and JCC SCADA System.
3. TOA Corporation (under Wasamitra Engineering), as “Chief Electrical Engineer” for Paiton – 3 Expansion Project, 815MW Coal Fired Power Plant, Contract Period: 20th September 2010 up to 21thFebruary 2010:
  • Design Construction of Temporary Power Distribution System at Project Site as per Load Analysis.
  • Manage All Electrical Group to Perform a Safety Work and Safety Electrical System at Project Site.
  • Manage Permit To Work for All Electrical Works at Live/Energized Electrical Distribution Board.
  • Coordination of Electrical Works with Paiton Energy (owner) and All Sub-Contractor for Safety and Electrical System Reliability.
  • Design and Submission of Distribution Board Schematic Diagram / Single Line Diagram As Built Drawing to Owner (Paiton Energy).
  • Modification, Test and Inspection of Distribution Board with Owner (Paiton Energy).
  • Manage Monthly and Quarterly Inspection of Distribution Panels, Tools and Equipments for All Sub-Contractor at Project Site then Report to Owner (Paiton Energy).
  • Design Cable Routing, Calculate Cable Ampicity for All Electrical Distribution Network at Project Site to Comply Owner’s Requirements of Safety and Reliability Electrical Installation at Plant.

Characteristics

  • Able to delegate manpower (strong leadership skills and 5 years experience at overall project site)
  • Has strong analysis and troubleshooting skills + 5 years experience as test and commissioning engineer
  • Able to work efficiently independently without direct supervision
  • Able to posses effective communication skills so as to deliver clear messages across to the working 
    partners
  • Able to work on team, adaptable, and 5 years experience work on teamwork successfully
  • Has strong sense of safety and security
I declare that the particulars stated in these curriculum vitae are true of the best of my knowledge and belief that I have not willfully suppressed any material or facts.

Paiton 3 - Jawa Timur, December 14, 2010
Ari Sulistiono 

0 komentar:

Posting Komentar

Daftar Isi